One sensor for water
quality, leaks and metering
One 55 mm sensor measures water quality, listens for leaks and reads the meter. Switch each on, sensor by sensor.
Signature · Reservoir 2Deviation
- pH7.4
- Conductivity512 µS/cm
- Free chlorine0.31 mg/L
Deviation flagged. Sample sent to the accredited laboratory.
Reference band, last 7 days
Hydraulics · Zone 3Leak
- Pressure3.4 bar
- Flow12.8 L/s
- Position22 m from N-014
Leak pre-located by three neighbouring sensors.
Pressure and acoustic level
Meter · M-212Alert
- Index004 812.350 m³
- Today1.9 m³
- Night flow38 L/h
Continuous night flow: leak after the meter.
Daily consumption, last 14 days
Switch on what you need, sensor by sensor.
Every capability runs on the same electronics. The deployment format sets which ones a sensor can offer; you choose which to switch on.
| Sensor | Format | Quality | Hydraulics | Metering |
|---|---|---|---|---|
| N-014Zone 3 | On-pipe node | Not available in this format | Not available in this format | |
| N-031Reservoir 2 | Water-access node | Not available in this format | ||
| N-052Zone 5 | On-pipe node | Not available in this format | Not available in this format | |
| M-212Meter | Meter module | Not available in this format | Not available in this format | |
| T-009Canteen | Tap module | Not available in this format | Not available in this format |
What each capability reads and reports.
-
Water quality
Tracks the electrochemical signature of the water against a reference set for each supply zone, and flags deviations so laboratory analyses are targeted.
QualityNeeds water access- Reads
- The electrochemical signature, against a reference set for each supply zone
- Delivers
- A deviation event and a sample directed to the accredited laboratory
- Needs
- A water-access node or a Tap module
- Limit
- The sensor flags, the accredited laboratory confirms. It does not replace a regulatory decision.
-
Water hydraulics
Listens through the pipe wall for leaks and tracks flow, pressure and water hammer. Neighbouring nodes pre-locate a leak on a pipe section.
HydraulicsOn the pipe or in the water- Reads
- Pressure waves carried by the pipe wall, sampled at a high rate
- Delivers
- A leak pre-located from neighbouring nodes, plus flow, pressure and water hammer
- Needs
- An on-pipe node or a water-access node
- Limit
- In situ calibration depends on the coupling and the pipe material.
-
Metering and services
Reads the meter magnetically, with no contact with the water, and warns the user of over-consumption, leaks and frost.
Metering and servicesOn the meter head- Reads
- The meter index, magnetically, with no contact with the water
- Delivers
- Communicating indexes and alerts: leak, over-consumption, backflow, frost
- Needs
- A meter module on the subscriber meter head
- Limit
- It does not monitor quality or hydraulics.
The quantities behind each capability.
Measured quantities and detected events, with no performance figures. PFAS are not measured: they stay a laboratory analysis.
Quality
- Physico-chemical
- Conductivity, salinity / TDS, temperature, pH, redox potential (ORP), dissolved oxygen, turbidity
- Metals
- Lead, copper, arsenic, mercury, cadmium
- Nitrogen and disinfection
- Nitrates, nitrites, free chlorine
- Organic matter, optical module
- Organic matter (CDOM), TOC / DOC, humic substances, colour, iron / manganese
- Descriptors and anomalies, AI
- Electrochemical fingerprint, charge transfer, contamination anomaly, pesticide anomaly, water-type classification
Hydraulics
- Hydraulics
- Flow, pressure, water hammer (transient)
- Acoustics
- Leak detection, multi-node pre-location, network leak location, asset listening (pumps, valves)
Metering and services
- Metering
- Remote meter reading, volume consumed
- Anomalies and alerts