Skip to content

Capabilities

Three capabilities.
One sensor.

Software functions, activated alone or combined. You concentrate value where it matters, and activate only what is useful, sensor by sensor.

Q

Capability Q

Vigilance through the sentinel effect

Quality

Continuous monitoring of the water’s electrochemical signature. The sensor detects deviations in real time and directs accredited laboratory analyses: it does not replace them, it makes them targeted. The same vigilance applies from one matrix to the next: drinking water, surface water, wastewater, shellfish waters, pools.

Operational value

  • COFRAC analyses triggered at the right moment, instead of systematic rounds.
  • Early, continuous detection of quality deviations.
  • Fewer non-productive samples, a better-targeted analytical effort.
Quality

What the sensor observes

01

Electrochemical signature

Signature tracking against a reference jointly established per distribution unit.

02

Vigilance parameters

Indicators detectable at useful thresholds: metals, free chlorine, nitrates, conductivity, depending on the water matrix.

03

Explicit physical limits

Measurement limits are owned: the sensor signals, the accredited laboratory qualifies.

The network sensor does not measure PFAS online and replaces no regulatory arbitration.

Quantifiable parameters

Physico-chemistry

  • Conductivity
  • Salinity / TDS
  • Temperature
  • pH
  • Redox potential (ORP)
  • Dissolved oxygen
  • Turbidity

Metals

  • Lead
  • Copper
  • Arsenic
  • Mercury
  • Cadmium

Nitrogen & disinfection

  • Nitrates
  • Nitrites
  • Free chlorine

Organic matter · optical module

  • Organic matter (CDOM)
  • TOC / DOC
  • Humic substances
  • Colour
  • Iron / Manganese

Descriptors & anomalies · AI

  • Electrochemical fingerprint
  • Charge transfer
  • Contamination anomaly
  • Pesticide anomaly
  • Water-type classification

PFAS excluded (laboratory-directed). A list of measurable parameters, with no performance figures.

H

Capability H

Leak detection & performance

Hydraulics

High-fidelity vibration listening. The sensor hears leaks through the wall, pre-locates them, and feeds yield optimisation, at the scale of a day, not a campaign.

Operational value

  • Leaks pre-located quickly, on priority sectors.
  • A reliable yield, a linear loss index (ILP) under control.
  • Listening to assets (pumps, valves) for predictive maintenance.
Hydraulics

What the sensor hears

01

Acoustic signature

Solid conduction of pressure waves in the pipe, captured at a high sampling rate.

02

Pre-location

A dense hydraulic mesh made possible by a unit cost far below a dedicated logger.

03

Hydraulic quantities

Flow, pressure, water hammer, ILP optimisation and yield calculation without flat-rate estimation.

In-situ calibration depends on the mechanical coupling and the pipe material.

Quantifiable quantities

Hydraulics

  • Flow
  • Pressure
  • Water hammer (transient)

Acoustics

  • Leak detection
  • Multi-node pre-location
  • Network leak location
  • Asset listening (pumps, valves)

Measured quantities and detected events, with no performance figures.

C

Capability C

Subscriber relationship, at the last metre

Metering & services

Communicating indexes and a direct relationship with the user. At the delivery point as at the point of use, the sensor serves reading, alerting and education about the resource.

Operational value

  • A direct subscriber relationship and resource sobriety.
  • Fewer disputes and unbilled volumes.
  • A decentralised tap module, closest to use.
Metering & services

What the sensor serves

01

Communicating indexes

Reliable reading at the delivery point, on the subscriber meter head.

02

Before / after meter detection

Over-consumption detected early, leak and frost alerts sent to the user.

03

Online services

Consumption tracking, transparency, fewer complaints and rebates.

The tap module runs on a long-life battery, replaceable by the user in seconds.

Quantities & services

Metering

  • Communicating index
  • Consumed volume

Anomalies & alerts

  • Leak before the meter
  • Leak after the meter
  • Over-consumption
  • Backflow
  • Imminent frost

Indexes, anomalies and alerts, with no performance figures.

Activation

Activate what matters, where it matters.

Every function is activatable on each sensor. The deployment format determines available capabilities; you choose which you activate.

Format Quality Hydraulics Metering
On-pipe node
Water-access node
Meter module
Tap module

Next

A platform to bring it together.

Capabilities feed VizO: collection, AI analysis and restitution, with data that stays yours.